This paper presents a new CHP solution based on a double shaft intercooled gas cycle with external combustion (EFGT cycle). This configuration exploits the turbocharger technology widely diffused in the automotive industry, taking advantage of the capital cost reduction due to the economy of scale typical of the automotive market. Thermodynamic calculations based on actual turbochargers maps available from manufacturers data are carried out in order to evaluate the performances of the system. It is shown that the system results competitive both with natural gas fuelled solutions such as internal combustion engines and microturbines achieving conversion efficiency of 25-30%, as well as with low grade fuels like biomass. For a 50. kW biomass system with a grate combustor boiler and turbine inlet temperature of 750. °C, an electric efficiency of 21% is obtained, which is higher than the available state of the art solutions based on ORC technology for this size. A preliminary design of the system is performed, including the sizing of the boiler, showing its technical feasibility, while complete economic evaluations will be considered in future works.
Innovative combined heat and power system based on a double shaft intercooled externally fired gas cycle.
IORA, Paolo Giulio;
2013-01-01
Abstract
This paper presents a new CHP solution based on a double shaft intercooled gas cycle with external combustion (EFGT cycle). This configuration exploits the turbocharger technology widely diffused in the automotive industry, taking advantage of the capital cost reduction due to the economy of scale typical of the automotive market. Thermodynamic calculations based on actual turbochargers maps available from manufacturers data are carried out in order to evaluate the performances of the system. It is shown that the system results competitive both with natural gas fuelled solutions such as internal combustion engines and microturbines achieving conversion efficiency of 25-30%, as well as with low grade fuels like biomass. For a 50. kW biomass system with a grate combustor boiler and turbine inlet temperature of 750. °C, an electric efficiency of 21% is obtained, which is higher than the available state of the art solutions based on ORC technology for this size. A preliminary design of the system is performed, including the sizing of the boiler, showing its technical feasibility, while complete economic evaluations will be considered in future works.File | Dimensione | Formato | |
---|---|---|---|
Iora-Silva 2013.pdf
solo utenti autorizzati
Descrizione: Articolo principale
Tipologia:
Full Text
Licenza:
DRM non definito
Dimensione
837.52 kB
Formato
Adobe PDF
|
837.52 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.