In the present research project, long anchorages provided with transverse reinforcement were tested with the aim of studying the confining effects of the stirrups. Particular attention was devoted to gathering detailed data on bar-to-concrete slip, splitting crack propagation and stirrup stresses. To carry out the pull-out tests, a special test set-up was built, and the friction between the specimen and the reaction plate was eliminated by resorting to a sophisticated design. The results show that (a) the maximum splitting crack opening increases for decreasing transverse-reinforcement diameter size and, under service loads, reaches remarkable values; (b) anchorage capacity increases with the stirrup index of confinement Ω up to an upper bound; (c) stirrup in specimens with a small amount of transverse reinforcement yielded under service loads. A comparison with the values prescribed by building codes evidence that the bond strength prescribed by both Eurocode 2 and ACI 318-95 code remarkably underestimates the experimental anchorage capacity for large values of the stirrup index of confinement.

Transverse reinforcement effects on anchored deformed bars

PLIZZARI, Giovanni;
1998-01-01

Abstract

In the present research project, long anchorages provided with transverse reinforcement were tested with the aim of studying the confining effects of the stirrups. Particular attention was devoted to gathering detailed data on bar-to-concrete slip, splitting crack propagation and stirrup stresses. To carry out the pull-out tests, a special test set-up was built, and the friction between the specimen and the reaction plate was eliminated by resorting to a sophisticated design. The results show that (a) the maximum splitting crack opening increases for decreasing transverse-reinforcement diameter size and, under service loads, reaches remarkable values; (b) anchorage capacity increases with the stirrup index of confinement Ω up to an upper bound; (c) stirrup in specimens with a small amount of transverse reinforcement yielded under service loads. A comparison with the values prescribed by building codes evidence that the bond strength prescribed by both Eurocode 2 and ACI 318-95 code remarkably underestimates the experimental anchorage capacity for large values of the stirrup index of confinement.
1998
Ateneo di appartenenza
PE8_3 Civil engineering, maritime/hydraulic engineering, geotechnics, waste treatment
Sì, ma tipo non specificato
Inglese
Internazionale
STAMPA
50
2
161
177
17
3
info:eu-repo/semantics/article
262
Plizzari, Giovanni; Deldossi, M. A.; Massimo, S.
1 Contributo su Rivista::1.1 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/162573
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 32
social impact