The accuracy of the sentinel node (SN) technique in the evaluation of lymph node involvement in melanoma was evaluated in 71 consecutive patients with localized disease and Breslow index >1 mm. Lymphoscintigraphy identified at least one SN in 70 of the 71 patients (98.5%). The following day 69 patients underwent selective SN excision. The SN was identified by portable probe. One hundred and twenty-two lymph nodes were removed, 14 (11.4%) of which were metastatic in 9 patients (13%). No metastases were found in 40 patients with Breslow <2 mm. Eight of the 9 patients with positive SNs underwent lymphadenectomy of the whole basin and in two patients new metastatic nodes were found. At 4-26 months' follow-up 1 of the 60 patients with negative SN (scalp melanoma with Breslow 6.2 mm) developed bilateral cervical metastatic nodes. Two more patients with Breslow 3.7 and 5 mm, respectively, developed liver and lung metastases. The remaining 57 patients are still disease free. Among the 9 patients with tumor-positive SNs, 1 was lost to follow-up, 3 died and 5 are still alive. Our data confirm the clinical reliability of the SN technique in melanoma; we feel the technique should be considered a standard tool in the evaluation of melanoma patients.

Sentinel node biopsy in melanoma: the experience of Brescia Civic Hospital.

GIUBBINI, Raffaele
2000-01-01

Abstract

The accuracy of the sentinel node (SN) technique in the evaluation of lymph node involvement in melanoma was evaluated in 71 consecutive patients with localized disease and Breslow index >1 mm. Lymphoscintigraphy identified at least one SN in 70 of the 71 patients (98.5%). The following day 69 patients underwent selective SN excision. The SN was identified by portable probe. One hundred and twenty-two lymph nodes were removed, 14 (11.4%) of which were metastatic in 9 patients (13%). No metastases were found in 40 patients with Breslow <2 mm. Eight of the 9 patients with positive SNs underwent lymphadenectomy of the whole basin and in two patients new metastatic nodes were found. At 4-26 months' follow-up 1 of the 60 patients with negative SN (scalp melanoma with Breslow 6.2 mm) developed bilateral cervical metastatic nodes. Two more patients with Breslow 3.7 and 5 mm, respectively, developed liver and lung metastases. The remaining 57 patients are still disease free. Among the 9 patients with tumor-positive SNs, 1 was lost to follow-up, 3 died and 5 are still alive. Our data confirm the clinical reliability of the SN technique in melanoma; we feel the technique should be considered a standard tool in the evaluation of melanoma patients.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/155652
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact