Laser Powder Bed Fusion (L-PBF) is turning out to be very promising for biomedical components production and stents are among the devices that would be suitable for tailor-made production. One of the most common stent types are the self-expandable, manufactured with Nitinol (NiTi). The use of NiTi alloy with L-PBF needs to be well controlled, as Ni evaporation during the process leads to significant variations in the final component properties. In the present work, prototype NiTi stents were produced via L-PBF and heat treated to examine the possibility of employing this technology for their application, also considering the Ni evaporation resulting from the layer-by-layer deposition. Samples were characterized through differential scanning calorimetry (DSC), microstructural observations, and compression tests in plate-to-plate configuration according to the standard. In parallel, a commercially available stent manufactured with traditional technology was tested for comparison.

Effect of Heat Treatments on Microstructure and Mechanical Properties of Nitinol Prototype Stents Produced by Laser Powder Bed Fusion

Abrami, Maria Beatrice
;
Tocci, Marialaura;Brabazon, Dermot;Pola, Annalisa
2023-01-01

Abstract

Laser Powder Bed Fusion (L-PBF) is turning out to be very promising for biomedical components production and stents are among the devices that would be suitable for tailor-made production. One of the most common stent types are the self-expandable, manufactured with Nitinol (NiTi). The use of NiTi alloy with L-PBF needs to be well controlled, as Ni evaporation during the process leads to significant variations in the final component properties. In the present work, prototype NiTi stents were produced via L-PBF and heat treated to examine the possibility of employing this technology for their application, also considering the Ni evaporation resulting from the layer-by-layer deposition. Samples were characterized through differential scanning calorimetry (DSC), microstructural observations, and compression tests in plate-to-plate configuration according to the standard. In parallel, a commercially available stent manufactured with traditional technology was tested for comparison.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/625765
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact