The objective and quantitative assessment of physical human-exoskeletons interaction (pHEI) represents a pressing necessity in the wearable robots field. This process remains of difficult execution, especially for early stage devices, in which the inclusion of human testing could pose ethical and safety concerns. This manuscript proposes a methodology for pHEI assessment based on an active dummy leg named Leg Replica, which is able to sense interaction forces while wearing an exoskeleton. We tested this methodology on a wearable active knee exoskeleton prototype, with the goal to evaluate the effects of a misalignment compensation mechanism. Through this methodology, it was possible to show how the misalignment compensation mechanism was able to reduce the interaction forces during passive exoskeleton motion. Such reduction was less evident when the exoskeleton was active. The tests allowed to identify specific points of improvements for the exoskeleton, enabling a more specific upgrade of the device based on these experimental results. This study demonstrates the ability of the proposed methodology to objectively benchmark different aspects of pHEI, and to accelerate the iterative development of new devices prior to human testing.

Systematic evaluation of a knee exoskeleton misalignment compensation mechanism using a robotic dummy leg

Stefano Massardi;David Rodriguez-Cianca
;
Matteo Lancini;
2023-01-01

Abstract

The objective and quantitative assessment of physical human-exoskeletons interaction (pHEI) represents a pressing necessity in the wearable robots field. This process remains of difficult execution, especially for early stage devices, in which the inclusion of human testing could pose ethical and safety concerns. This manuscript proposes a methodology for pHEI assessment based on an active dummy leg named Leg Replica, which is able to sense interaction forces while wearing an exoskeleton. We tested this methodology on a wearable active knee exoskeleton prototype, with the goal to evaluate the effects of a misalignment compensation mechanism. Through this methodology, it was possible to show how the misalignment compensation mechanism was able to reduce the interaction forces during passive exoskeleton motion. Such reduction was less evident when the exoskeleton was active. The tests allowed to identify specific points of improvements for the exoskeleton, enabling a more specific upgrade of the device based on these experimental results. This study demonstrates the ability of the proposed methodology to objectively benchmark different aspects of pHEI, and to accelerate the iterative development of new devices prior to human testing.
File in questo prodotto:
File Dimensione Formato  
RehabWeek_abstract_Misalignment_compensation_evaluation_Reviewed_2023.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: PUBBLICO - Creative Commons 4.0
Dimensione 3.2 MB
Formato Adobe PDF
3.2 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/605105
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact