In this work, the possibility to align cells dispersed in water by means of standing flexural plate waves (FPWs) in an underlying substrate has been explored by designing and fabricating a piezoelectric MEMS transducer. The MEMS exhibits a 6x6 mm2 cavity etched out in a silicon substrate forming a volume where cells dispersed in liquid can be steered under electronic control. The diaphragm of the cavity is composed of silicon (Si) and an aluminum nitride (AlN) layer. The generation of FPWs of the A0 mode in the diaphragm is achieved by applying proper excitation voltages to two metal interdigital transducers (IDTs). In turn, acoustic waves are transferred in the liquid, generating a one-dimensional acoustic field pattern thus steering and trapping the dispersed cells in distinct positions. The MEMS device has been fabricated by using the PiezoMUMPs process and experimentally tested by exploiting a tailored front-end circuit. The cavity has been loaded with inert fibroblasts cells with an approximate diameter of 15 μm dispersed in demineralized water with a concentration in the order of 105 cells/ml. By properly driving two IDTs, lines of cells spaced by half wavelength λ/2 = 56 μm have been achieved at 12.5 MHz, in good agreement with theoretical expectations.

Flexural Plate Wave Piezoelectric MEMS Transducer for Cell Alignment in Aqueous Solution

Nastro A.;Bau' M.;Ferrari M.;Ferrari V.
2023-01-01

Abstract

In this work, the possibility to align cells dispersed in water by means of standing flexural plate waves (FPWs) in an underlying substrate has been explored by designing and fabricating a piezoelectric MEMS transducer. The MEMS exhibits a 6x6 mm2 cavity etched out in a silicon substrate forming a volume where cells dispersed in liquid can be steered under electronic control. The diaphragm of the cavity is composed of silicon (Si) and an aluminum nitride (AlN) layer. The generation of FPWs of the A0 mode in the diaphragm is achieved by applying proper excitation voltages to two metal interdigital transducers (IDTs). In turn, acoustic waves are transferred in the liquid, generating a one-dimensional acoustic field pattern thus steering and trapping the dispersed cells in distinct positions. The MEMS device has been fabricated by using the PiezoMUMPs process and experimentally tested by exploiting a tailored front-end circuit. The cavity has been loaded with inert fibroblasts cells with an approximate diameter of 15 μm dispersed in demineralized water with a concentration in the order of 105 cells/ml. By properly driving two IDTs, lines of cells spaced by half wavelength λ/2 = 56 μm have been achieved at 12.5 MHz, in good agreement with theoretical expectations.
2023
Lecture Notes in Electrical Engineering
Ateneo di appartenenza
PE7_5 Micro- and nanoelectronics, optoelectronics
PE7_4 Systems engineering, sensorics, actorics, automation
PE7_2 Electrical and electronic engineering: semiconductors, components, systems
Esperti anonimi
Inglese
53rd Annual Meeting of the Italian Electronics Society, SIE 2022
7-9 September, 2022
Pizzo Calabro (VV) - Italy
Nazionale
1005
122
127
6
978-3-031-26065-0
978-3-031-26066-7
Springer Science and Business Media Deutschland GmbH
Acoustic waves; Cell alignment; Flexural plate waves; MEMS; Piezoelectric; PiezoMUMPs; Transducer
Goal 3: Good health and well-being
none
Nastro, A.; Bau', M.; Ferrari, M.; Rufer, L.; Basrour, S.; Ferrari, V.
273
info:eu-repo/semantics/conferenceObject
6
4 Contributo in Atti di Convegno (Proceeding)::4.1 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/582987
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact