Regulations and normative framework strongly affect requirements and potential design constraints of devices, especially in critical environments like the medical field, characterized by a complex interaction among design, therapy procedures and user needs. In order to optimize the design process, the awareness of the designer about the compound information net generated by the required documentation becomes therefore fundamental. Depicting a custom mapping of required data and referring documents for the development and commercialization of a medical device as required by the Conformité Européenne (CE) marking process, this paper presents a design approach directly suitable for robotic rehabilitation systems, which aims at easing the regulations compatibility of the designed product. This method is applied to the illustrative case study of the LEPRE (LEg Programmable REhabilitation) robotic system, with particular attention to data collection and analysis for the evaluation of clinical background and demonstration of equivalence required by the device clinical evaluation report, according to MEDical DEVices (MEDDEV) 2.7/1 guidelines. Indications for the modifications required to adapt it to further application fields are also suggested.

Design Approach of Medical Devices for Regulation Compatibility: A Robotic Rehabilitation Case Study

Formicola R.;Ragni F.
;
Bissolotti L.;Amici C.
2021-01-01

Abstract

Regulations and normative framework strongly affect requirements and potential design constraints of devices, especially in critical environments like the medical field, characterized by a complex interaction among design, therapy procedures and user needs. In order to optimize the design process, the awareness of the designer about the compound information net generated by the required documentation becomes therefore fundamental. Depicting a custom mapping of required data and referring documents for the development and commercialization of a medical device as required by the Conformité Européenne (CE) marking process, this paper presents a design approach directly suitable for robotic rehabilitation systems, which aims at easing the regulations compatibility of the designed product. This method is applied to the illustrative case study of the LEPRE (LEg Programmable REhabilitation) robotic system, with particular attention to data collection and analysis for the evaluation of clinical background and demonstration of equivalence required by the device clinical evaluation report, according to MEDical DEVices (MEDDEV) 2.7/1 guidelines. Indications for the modifications required to adapt it to further application fields are also suggested.
File in questo prodotto:
File Dimensione Formato  
2020_ICT4AWE_V103.pdf

gestori archivio

Tipologia: Full Text
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 350.99 kB
Formato Adobe PDF
350.99 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/564440
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 4
social impact