As bacterial infection diseases represent a relevant threat for human health worldwide, many efforts are spent in accelerating the diagnostic process of biological specimens. The WASPLab automated platform, by COPAN Italia S.p.A., detects bacterial growth by processing the images of the Petri dishes containing a sample to analyze. This work presents a study performed on a developed system that exploits impedance measurement to monitor bacterial growth in Petri dishes in real time. It is part of an activity aiming at system integration in the WASPLab, to enhance its monitoring capabilities and flexibility. Through repeated 24-h tests executed with the system, we successfully detected S. aureus growth in Petri dishes that were inside one of the WASPLab incubators, starting from impedance measurements performed at 50–150 Hz. In particular, depending on the parameter being observed, detection time was between four and six hours, for an initial bacterial concentration in the order of 4.5· 10 7 CFU/ml. These preliminary results represent the first step for evaluating system integration in the WASPLab.

Study toward the integration of a system for bacterial growth monitoring in an automated specimen processing platform

Bellitti, Paolo;Bona, Michele;Fontana, Stefania;Sardini, Emilio;Serpelloni, Mauro
2019-01-01

Abstract

As bacterial infection diseases represent a relevant threat for human health worldwide, many efforts are spent in accelerating the diagnostic process of biological specimens. The WASPLab automated platform, by COPAN Italia S.p.A., detects bacterial growth by processing the images of the Petri dishes containing a sample to analyze. This work presents a study performed on a developed system that exploits impedance measurement to monitor bacterial growth in Petri dishes in real time. It is part of an activity aiming at system integration in the WASPLab, to enhance its monitoring capabilities and flexibility. Through repeated 24-h tests executed with the system, we successfully detected S. aureus growth in Petri dishes that were inside one of the WASPLab incubators, starting from impedance measurements performed at 50–150 Hz. In particular, depending on the parameter being observed, detection time was between four and six hours, for an initial bacterial concentration in the order of 4.5· 10 7 CFU/ml. These preliminary results represent the first step for evaluating system integration in the WASPLab.
2019
Lecture Notes in Electrical Engineering
Ateneo di appartenenza
PE7_4 Systems engineering, sensorics, actorics, automation
PE7_2 Electrical and electronic engineering: semiconductors, components, systems
Esperti anonimi
Inglese
4th National Conference on Sensors, 2018
2018
ita
Internazionale
539
445
454
10
9783030043230
Springer Verlag
Bacterial growth detection; Impedance measurement; WASPLab platform; Industrial and Manufacturing Engineering
http://www.springer.com/series/7818
no
none
Bellitti, Paolo; Bona, Michele; Fontana, Stefania; Sardini, Emilio; Serpelloni, Mauro
273
info:eu-repo/semantics/conferenceObject
5
4 Contributo in Atti di Convegno (Proceeding)::4.1 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11379/521111
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact