In this article a telemetric system for relative-humidity measures is proposed. The contactless transmission problem is analyzed also when the distance between readout circuit and sensing circuit changes. Three hydrophilic polymers are deposited on parasitic capacitance of sensing system. The sensitivities to the relative humidity and distance are calculated. The measurement method has been tested in the laboratory and the experimental results are reported.
A distance compensated telemetric humidity sensor based on the parasitic capacitance variation
MARIOLI, Daniele;SARDINI, Emilio;SERPELLONI, MAURO;TARONI, Andrea
2006-01-01
Abstract
In this article a telemetric system for relative-humidity measures is proposed. The contactless transmission problem is analyzed also when the distance between readout circuit and sensing circuit changes. Three hydrophilic polymers are deposited on parasitic capacitance of sensing system. The sensitivities to the relative humidity and distance are calculated. The measurement method has been tested in the laboratory and the experimental results are reported.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.